1、暖衛(wèi)工程概況
暖衛(wèi)工程包括給水系統(tǒng)、排水系統(tǒng)、消防系統(tǒng)、雨水系統(tǒng)、空調(diào)冷卻水系統(tǒng)。
1.1 給水系統(tǒng)
水源為室外給水管網(wǎng)接出—根DN 150引入管,接人大樓地下—層。根據(jù)水壓,給水豎向分高低兩個(gè)區(qū),高區(qū)為四至十六層,由屋頂水箱供給;低區(qū)為地下二層至地上三層,該區(qū)利用場(chǎng)區(qū)給水管直接供水。
1.2 排水系統(tǒng)
室內(nèi)排水系統(tǒng)為污水、廢水合流系統(tǒng),地上部分直接排出室外;首層單獨(dú)排出室外;地下部分分區(qū)設(shè)置集水坑匯集地下室污、廢水,然后用潛水泵提升排出室外,潛水泵由集水坑水位自動(dòng)控制;糞便污水經(jīng)室外化糞池處理后,排人市政管道。
1.3 消防系統(tǒng)
1.3.1 本樓消防系統(tǒng)由消火栓系統(tǒng)、自動(dòng)噴水滅火系統(tǒng)及氣體滅火系統(tǒng)組成。
1.3.2 消火栓系統(tǒng)水源為地下一層的消防水池,其貯水量432m3。平時(shí)由屋頂水箱供水,屋頂水箱貯存消防水量18m3。系統(tǒng)上、下成環(huán),除水箱間、變配電間外,其它各層均設(shè)有消火栓保護(hù)。室外設(shè)有三套消防水泵接合器,供消防車向系統(tǒng)供水。
1.3.3 自動(dòng)噴水滅火系統(tǒng)水源為地下一層的消防水池,自動(dòng)噴灑用
1 warming Health Project Overview
Warm Health Project, including water supply systems, drainage systems, fire systems, water systems, air conditioning cooling water system.
1.1 Water Supply System
Water for outdoor access a water supply network - the introduction of the root DN 150 pipes, building underground access - level. Under water pressure, water level of the two vertical sub-area, high area for the 4-16 level, from the roof tank supply; low area for the basement level to the ground three, the district used the site area to direct water supply pipes.
1.2 Drainage System
Interior drainage system for the sewage, waste water confluence system, shoot directly into the open air; the first floor alone exhausted to the outside; underground basement area set sump sewage collection, wastewater, and then discharged with a submersible pump to enhance outdoor, submersible pump water from the sump automatic control; fecal sewage treated by septic tanks outside, drained municipal pipes.
1.3 Fire Protection System
1.3.1 The floor system consists of fire hydrant system, automatic fire sprinkler system and gas system components.
1.3.2 Hydrant system for the underground water level of the fire pond, the water storage 432m3. Usually from the roof tank water supply, fire water storage tank roof of 18m3. System, the next into the ring, in addition to the water tank, the variable power distribution room, the other floors are equipped with fire hydrant protection. With three sets of outdoor fire pump adapter for the fire water supply to the system.
1.3.3 fire sprinkler system for the underground water level of the fire pool, automatic sprinkler use