室內氣體消防滅火系統安裝技術交底-北京建工集團.doc
進入下載頁
1 范圍
本工藝標準適用于民用和一般工業(yè)建筑中設置的二氧化碳滅火系統,鹵代烷1211、1301滅火系統的管道及設備安裝。
2 施工準備
2.1 接到任務后,認真熟悉施工圖紙,對照裝修圖并結合施工現場檢查管路及噴嘴位置是否相吻合,如存在問題,應及時與設計協商解決并辦理洽商手續(xù)。根據工程特點確定施工方法,配備所需各項資源。
2.2 設備材料:
2.2.1 消防氣體滅火系統主要設備材料的選用應符合6一1"消防工程安裝的通用要求"的有關內容。
2.2.2 主要設備:滅火劑儲存容器及系統組件包括單向閥、容器閥、選擇閥、閥驅動裝置和噴嘴等。這些系統組件均應給國家質量監(jiān)督檢測中心檢測合格。系統中
1 Scope
This technology is applicable to civil and general industrial buildings set carbon dioxide fire extinguishing systems, Halon fire extinguishing system 1211,1301 pipe and equipment installation.
2 construction preparation
2.1 After receiving the task seriously familiar with the construction drawings, control construction site fitting-out plans and combined piping and nozzle checking whether location of match, such as problems should be resolved through consultation and design time and go through the negotiation process. Determined based on the engineering characteristics of construction method, with the resources required.
2.2 Equipment and Materials:
2.2.1 The main fire gas fire extinguishing system should comply with the selection of equipment and materials 6 1 1 "to install the Universal fire engineering requirements" of the content.
2.2.2 Main Equipment: fire extinguishing agent storage container and system components, including a one-way valve, the container valve, selector valve, valve actuators and nozzle so. The system components should be addressed to the State Quality Supervision and Inspection Center qualified. System